Local SYR endpoints so your device can talk to Home Assistant without the cloud.
- DNS override required: point these hostnames to your HA host IP:
syrconnect.de,syrconnect.consoft.de,connect.saocal.pl,maintenance.syrconnect.de. - HTTPS certificates: only needed if your device firmware uses HTTPS (≈1.9+). Place in
/config:syr_cert.pemsyr_key.pem
- Add the integration: Settings → Devices & Services → Add Integration → “SYR Connect Local”.
- HTTP Port: 80
- HTTPS Port: 443 (optional)
- Enable HTTPS only if your device actually calls HTTPS.
- Entities appear after the first device data; controls (e.g., regeneration interval, salt volume) update after the device’s next poll.
For contributors or local testing, run HA from this repo.
Prerequisites:
- Docker and Docker Compose
- DNS override as above so your SYR device hits this host
Quick start:
# From the repo root
docker compose up -d
# Follow first boot logs
docker logs home-assistant --followPorts (from docker-compose.yml):
- 8123 → Home Assistant UI
- 80 → SYR Connect Local HTTP (firmware ≈ 1.7)
- 443 → SYR Connect Local HTTPS (firmware ≈ 1.9+)
- Open HA → Settings → Devices & Services → Add Integration → “SYR Connect Local”.
- Configure ports and HTTPS as above.
- Submit and wait for your device to connect. Entities will appear after first data.
The integration automatically creates entities across multiple platforms:
- Sensors: Water hardness (inlet/outlet), salt tank capacity/volume, flow rate, pressure, remaining capacity, regeneration counts, water consumption (daily/weekly/monthly)
- Binary Sensors: Regeneration active per tank, alarm status
- Buttons: Start regeneration, manual refresh
- Numbers: Regeneration interval (days), salt volumes per tank, water hardness setters
- Selects: Regeneration weekday preferences (pre-defined schedules or custom)
- Time: Regeneration schedule time picker
Key Controls:
- Start Regeneration button (entity category: config) triggers an immediate regeneration (
setSIR=0) - Regeneration interval/weekday/time: Configure scheduling via number, select, and time entities
- Salt volumes: Adjust per-tank salt levels via number entities
- Water hardness: Set inlet/outlet hardness values and unit preference
Services:
syr_connect_local.start_regeneration: Trigger immediate regenerationsyr_connect_local.update_parameter: Generic parameter update for advanced automation
Example device view with controls and sensors:
- Polling responses now include only getters; setters are sent only when you press the button or call a service.
- Command flow is logged at INFO level:
Command queued for device <serial>: <cmd>=<value>Sending N commands to device <serial>: ...
Key getters (read-only data the device sends):
- Regeneration:
getRPD(interval days),getRPW(weekdays),getRTH(hour),getRG1/2/3(active per tank) - Water Quality:
getIWH(inlet hardness),getOWH(outlet hardness),getWHU(hardness unit) - Salt Tanks:
getSV1/2/3(volume kg),getCS1/2/3(capacity %),getSD1/2/3(days remaining),getSW1/2/3(weeks remaining) - Flow & Pressure:
getFLO(L/min),getPRS(bar ×10),getFCO(flow counter),getRES(remaining capacity liters) - System:
getALM(alarm),getSTA(status),getPST(power state) - Consumption:
getTOF(today),getYEF(yesterday),getCWF(this week),getCMF(this month),getCOF(total), daily breakdown per weekday
Key setters (commands we send to the device):
- Regeneration:
setSIR(trigger immediate),setRPD(interval days),setRPW(weekdays),setRTH(hour) - Water Hardness:
setIWH(inlet),setOWH(outlet),setWHU(unit: 0=°dH, 1=°fH, 2=°eH) - Salt Volumes:
setSV1/2/3(per tank, kg)
- Power switch: Control is experimental and commented out pending device-specific testing
- Multi-device support: Available but currently untested in production
- DVGW Compliance: The regeneration interval is limited to 4 days maximum in accordance with DVGW (DIN 1988 / DIN EN 806 / DIN EN 1717) standards. A compliance sensor will alert if the device interval exceeds this limit—the user is responsible for regulatory compliance.
- Polling behavior: All periodic polls request only getters; setters are sent only when you change a control or call a service
- Asynchronous updates: The integration queues setters until the device's next poll, then requests a refresh to show the updated value
- Ensure your network/DNS points the SYR domains to your HA host IP
- Secrets and HA runtime files are ignored by .gitignore; keep device-specific config in
homeassistant/config
If enabling HTTPS, place a certificate and key in HA’s /config:
/config/syr_cert.pem/config/syr_key.pem
Generate self-signed certs for local testing:
openssl req -x509 -newkey rsa:2048 -nodes \
-keyout syr_key.pem -out syr_cert.pem -days 3650 \
-subj "/CN=syrconnect.local" \
-addext "subjectAltName=DNS:syrconnect.de,DNS:syrconnect.consoft.de,DNS:connect.saocal.pl,DNS:maintenance.syrconnect.de,DNS:localhost,IP:127.0.0.1"
docker cp syr_cert.pem home-assistant:/config/syr_cert.pem
docker cp syr_key.pem home-assistant:/config/syr_key.pemThen enable HTTPS in the integration options.
# HTTP
curl -s http://localhost:80/WebServices/SyrConnectLimexWebService.asmx/GetBasicCommands -d "<xml/>"
# HTTPS (self-signed)
curl -s https://localhost:443/WebServices/SyrConnectLimexWebService.asmx/GetBasicCommands -k -d "<xml/>"Follow logs for activity:
docker logs home-assistant --follow 2>&1 | grep -i syr_connect_localEnable in HA → Integration Options → “Debug endpoints”.
curl -s http://<HA_HOST_IP>:80/status
curl -s http://<HA_HOST_IP>:80/echoDisable when done (they return 404 if disabled).
This project is licensed under the MIT License - see the LICENSE file for details.
- Protocol documentation: syrlex2mqtt by Richard Schaller
- Inspired by the ioBroker.syrconnect project
Common Issues:
- Entities not appearing: Check DNS overrides are set correctly and device is connected to the network
- HTTPS connection fails: Verify certificates are in
/configand device firmware supports HTTPS - Commands not updating: Wait for the device's next poll cycle (default: every 5 minutes)
Getting Help:
- Enable debug logging in HA:
loggerintegration withsyr_connect_localset to DEBUG - Check existing issues
- Create a new issue with:
- Home Assistant version
- Integration version
- Device model and firmware version
- Relevant debug log entries
- Description of the problem